He used the 565/514-7 flange to mount the railing at the top of the steps, and the 567-7 Post Return to mount to the post. Jerry Peck. For clarification, a “riser” is the vertical portion of a stair. By Mike Guertin Issue 257 - Feb/March 2016.

• A round handrail diameter must be between 1.25 and 2 inches. How many steps are allowed before a handrail is required? shall be not less than 36 inches in clear width at all points above the handrail height and the handrail may project no more than 4 ½ inches on either side of the stairway. Insurance companies can accept the local laws or require handrails for rises of any size. Stairways shall have handrails on each side. From the 2006 IBC. We just paid alot of money for the retaining wall and steps and the contractor did not include a handrail. A two riser minimum would translate to two steps. (c) The top of stair railings, handrails and handrail extensions installed on or after April 3, 1997, shall be at a vertical height between 34 and 38 inches above the nosing of treads and landings. Handrail Required? How Many Exterior Steps Require A Handrail Back to: ← Code Requirements for Handrails on Exterior Standard Stair Rail Do I Need A Handrail For 3 Steps To reduce the risk of injury, Greg added an outdoor handrail to his pool area steps using a modified version of one of our Wall and Surface Mounted Stair Railing Kits. I've been collecting photos and notes on the question of how people solve the handrail problem on very wide steps for quite some time. Back to: ← Code Requirements for Handrails on Exterior Standard Stair Rail Minimum railing distance means the walking space between a handrail on one wall and an adjacent wall that has no handrail. Re: exterior steps requirements First, you need to define "steps" as that is … The building code does not refer to the number of “steps” but it does require a handrail when there are two or more “risers”. For a commercial office building that has other access points (including accessible routes). At least one handrail must be provided for stairs with four or more risers or 30 inches of ascent. Similar Threads: Exterior walkpaths - - Question for Texas boys and girls! Count the number of risers, and check the nearby topography. But they need to be in the right place, at the right height and graspable: The top of the handrail should be positioned between 900mm and 1000mm above the pitch line or floor. The need for a handrail is based on the rise (height) of the stairway, not the number of steps. risers. On 2020-01-29 - by (mod) - how people solve the handrail problem on very wide steps. - R311.5.6 Handrails. Handrails should give firm support and allow a firm grip. Exterior Installation of Gas Flex Line; Exterior JB; Staining on exterior wall near A/C ; Brick Veneer Exterior Wall 90 deg inside joint; 05-31-2009, 08:44 PM #2. State laws regarding heights of these supports require a guard to be 4 to 8 inches higher than the handrail requirement. From the 2006 IRC. How many steps require a handrail? For example, a 2-by-4 is not considered a handrail because it cannot be safely gripped. When you have just one railing on a staircase, the inside (stair-side) edge of the railing must be at least 31 1/2 inches away from the wall on the other side of the staircase. Handrails, however, are required on both sides of … Thus, the minimum clear width of a stairway at or below the handrail, when one is required, is 31 ½ inches, and 27 inches where two are required.